Reference catalogs · instrument
Radiation Heat Transfer Calculator
The current ledger marks this instrument verified with errata that must be applied at binding time.
Ledger state
The current ledger marks this instrument verified with errata that must be applied at binding time.
- Area
- Thermodynamics, Fluids & Aero
- Tranche
- tranche-4
- Evidence ID
- t4-144
- Ledger rows
- 1
No ledger note is attached.
Review findings
The instrument can be correct for blackbody or gray-surface-to-black-surroundings exchange with F=1, and for the restricted equal-area two-surface enclosure formula. As specified, it claims broader graybody and view-factor capability than the formulas support; add the missing geometric radiation-resistance terms or narrow the claims and inputs.
Formula and scope findings
- The formula q=εσA(T1⁴−T2⁴) is valid only for a gray surface radiating to a blackbody enclosure or effective black surroundings with view factor F=1; it is not a general two-surface graybody formula.
- The two-surface enclosure formula σA(T1⁴−T2⁴)/[1/ε1+1/ε2−1] requires two diffuse-gray, opaque, isothermal surfaces with equal area and mutual view factors F12=F21=1. It is not valid for arbitrary areas or the supplied view-factor input.
- View factors are listed as inputs but are absent from both formulas. General unequal-area or partial-view configurations require geometric radiation-resistance terms involving area and view factor.
- The specification claims blackbody/graybody exchange and simple view factors, but the formulas do not distinguish the blackbody-surroundings case from the two-gray-surface case.
Unit assumptions
- Temperatures must be absolute temperatures in kelvin; Celsius or Fahrenheit values must be converted before taking the fourth power.
- Area A is in square metres and the resulting heat rate q is in watts.
- Emissivities ε, ε1, and ε2 are dimensionless and must satisfy 0≤ε≤1; physical opaque-surface calculations normally require positive emissivity.
- The Stefan-Boltzmann constant is σ=5.670374419×10^-8 W·m^-2·K^-4.
- The positive sign convention is net heat transfer from surface 1 to surface 2 or the surroundings.
Boundary hardening
Recorded hazards
- Division by zero or nonphysical results occur if ε1 or ε2 is zero in the two-surface denominator.
- The denominator formula becomes invalid when the surfaces do not have equal area and mutual view factor one.
- Missing view-factor usage can cause large errors for partial visibility, separated surfaces, or enclosure geometries.
- Negative, zero, or non-absolute temperatures are invalid for this radiation formula; temperatures must be positive kelvin.
- Emissivities outside the interval 0 to 1 are nonphysical.
- The result can be negative when T1<T2; the interface must clearly label this as heat transfer from surface 2 toward surface 1.
- An emissivity table needs material, wavelength, temperature, and surface-condition assumptions; tabulated emissivity is not universally a single constant.
- The honest label is incomplete because it does not explicitly state the equal-area, F=1, diffuse-gray, opaque, isothermal assumptions behind the two-surface formula.
Errata and corrections
Tranche errata
q_net_W · vector 1
616.9367
6169.395
exactly 10x low; her v2/v4 verify with same sigma
Inspectable example
4 review vectors are recorded. One source-bound sample is shown below.
{
"inputs": {
"formula": "q=εσA(T1^4−T2^4)",
"epsilon": 1,
"area_m2": 2,
"T1_K": 500,
"T2_K": 300,
"view_factor": 1
},
"expected_outputs": {
"q_net_W": 616.9367368
},
"working": "T1^4=500^4=62,500,000,000 K^4. T2^4=300^4=8,100,000,000 K^4. Difference=54,400,000,000 K^4. q=1×(5.670374419×10^-8)×2×54,400,000,000. q=616.9367368 W."
}
Sources and evidence
These pointers bind the page to evidence. They do not grant authority or collapse verification into deployment.
VERIFIED_LEDGER.json · VERIFIED_WITH_ERRATAevidence-tranche4/tranche4-results.json